Propz Me Career FORNEY IGNITER PDF

FORNEY IGNITER PDF

The HESI is a Class 3 Igniter used for direct spark ignition of oil or gas igniters, small burners, and combustion turbines. Forney’s High Energy Spark Igniter (HESI) provides a highly reliable, non-fouling source of ignition for oil or gas igniters or small burners. The Forney horn igniter is designed to be a direct replacement for the OEM igniter on tangentially fired boilers. This igniter features improvements such as the. The MAXFire® Series gas igniter incorporates the “protected primary combustion zone” design in each of the 5 capacities available. MAXFire® gas igniters provide the most reliable source of energy for main flame ignition, flame stabilization, and boiler warm-up.

Author: Tut Faetaur
Country: Jordan
Language: English (Spanish)
Genre: Automotive
Published (Last): 25 August 2005
Pages: 15
PDF File Size: 14.87 Mb
ePub File Size: 11.80 Mb
ISBN: 703-9-76882-374-7
Downloads: 97602
Price: Free* [*Free Regsitration Required]
Uploader: Mazuzshura

This igniter features improvements such as the high energy spark igniter HESIoptical flame detector and the ignition air distribution ring. Return to top of page. As an option, a mount tube can be provided to support the igniter. Other changes implemented included checking air flow ifniter scanner fans, iggniter the time sequence on oil valves, and performing bi-weekly preventive maintenance on the igniters.

The remaining HESI components consist of a positioning rod, cable and power unit. The Forney horn igniter is designed to be a direct replacement for the OEM igniter on tangentially fired boilers.

This Class I igniter is located in a tilting tangentially fired boiler adjacent to the main fuel nozzle. Return to top of page. Horn Igniter The Forney horn igniter is designed to be a direct replacement for the OEM igniter on tangentially fired boilers. Both horn igniter assemblies consist of a mounting plate, an oil or gas gun for the single fuel horn igniter or a combination oil and gas gun for the dual fuel horn igniter, a High Energy Spark Igniter HESIa combustion air tube, an optional flame detector, and a horn.

  KANTECH KT 400 PDF

Oil Igniter Reliability Optimized by AEP-Forney Team

As a result this igniter is self-stabilized, highly reliable and requires virtu …. The HESI spark tip is a nonfouling, surface-gap tip which is replaceable as a unit by a threaded connection.

A factory mounted NEMA-4 junction box with all on-board electrical devices pre-wired to terminals is a standard feature which reduces installation time.

It was also identified that the ceramic insulators in many of the tips were broken or had cracks from being dropped on the burner deck during maintenance, and this caused malfunctions in the spark tips which required replacement. The Q87 is 4 inches in diameter with a self-stabilizing diffuser and a high energy spark igniter.

MaxFire® Series Gas Igniter – Forney Corporation

Flexible Single Tube igniters. The spark rod features a self-cleaning surface-gap spark tip that is easily replaceable via a threaded connection. Return to top of page. Forney and plant personnel did further root cause analysis to identify additional adjustments and countermeasures.

Natural gas or propane Minimum Length: Flexible Single Tube igniters. The HESI produces a consistent spark due to its foul resistant design, while the optical detector proves flame without physical contact.

WC across device Length:. Product Overview Product Overview The Q is a self-contained Class 1 oil or gas igniter used for burner ignition, stabilization or boiler warm-up. This igniter features improvements such as the high energy spark igniter HESIoptical flame detector and the ignition air distribution ring. The Q87 is 4 inches in diameter with a self-stabilizing diffuser and a high energy spark igniter.

  LA FABULA DE LAS ABEJAS DE MANDEVILLE PDF

Forney Ignition & Combustion Horn Igniter – Forney Corporation

The Forney horn igniter is designed to be a direct replacement for the OEM igniter on tangentially fired boilers. The problem solving approach was based on the PDCA Plan-Do-Check-Adjust model identifying specific actions, checks, and adjustments to be carried out before scheduled outages. Atomization takes place at the rear of the igniter away iyniter the heat of the tip resulting in no fouling or need for cleaning.

Application Flexibility The protected primary combustion zone ensures reliable operation in multiple environments. With a change-out of the internals, the Q87 can switch from firing one fuel to another.

It is also the choice when both air and steam atomization is required for No. Return to top of page. The HESI is a Class 3 Igniter used for direct spark ignition of oil or gas igniters, small burners, and combustion turbines. A joule HESI provides the ignition source for the fuel. WC above furnace pressure Length: These three features combine to produce a highly reliable igniter. Return to top of page. Combustion air is provided from the windbox.

The controlled mixture of fuel and air in the primary combustion zone results in a highly reliable, stable igniter flame.